Home /

2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With

Send your message to this supplier
*From:
Your email address is incorrect!
To:Ningbo Brando Hardware Co., Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V from wholesalers
  • Buy cheap 2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V from wholesalers
  • Buy cheap 2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V from wholesalers
  • Buy cheap 2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V from wholesalers

2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V

Ask Latest Price
Brand Name:Brando
Model Number:DMF-Z-62S
Certification:CE
Price:Negotiation
Payment Terms:L/C, T/T, Western Union,Paypal
Supply Ability:100000 pieces per month
Delivery Time:Negotiation
Company Data
Verified Supplier
Contact Person Brandon Bao
Business Type: Manufacturer Distributor/Wholesaler Exporter Seller
Officials: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V


Application:

Electromagnetic pulse valve, also called diaphragm valve acts as a “switch” for compressed air in the dust clean blowing system for pulse bag filters. It is controlled by the electric signals from the pulse-jet control device. This system cleans the filter bags cluster by cluster with high-pressure blowing to keep the pressure resistance of the baghouse within a pre-set range, and thus ensure the processing capability and the dust-collecting efficiency of the baghouse.


Technical data of SBFEC Replacement Right Angle Impulse Diaphragm Valves:

Model No
Nominal diametrer
Number of diaphragms
Inlet
Outlet
Weight (kg)
mm
inch
DMF-Z-20
Φ20
3/4''
1
G3/4''
G3/4''
0.65
DMF-Z-25
Φ25
1'''
1
G1''
G1''
0.8
DMF-Z-40S
Φ40
1 1/2''
2
G1 1/2''
G1 1/2''
1.4
DMF-Z-50S
Φ50
2''
2
G 2''
G2
2.4
DMF-Z-62S
Φ62
2 1/2''
2
G2 1/2''
G2 1/2''
3.5
DMF-Z-76S
Φ76
3''
2
G3''
G3''
4.3
DMF-Z-90S
Φ90
3 1/2''
2
G3 1/2''
G3 1/2''
5.75
DMF-Z-102S
Φ102
4''
2
G4''
G4''
7.3
DMF-20L-B
Φ20
3/4''
1
G3/4''
Φ27
0.75

Tips: All related accessories are also sold, like Pulse Controller, Diaphragm, Solenoid Coil and Armature Assembly.

Main dimension of DMF-Z-62S SBFEC Type Dust Collector Valve:

2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V


Detailed pictures of DMF-Z-62S SBFEC Replacement Solenoid Valve:

2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V


DMF-Z-62S right angle dust collector pulse valve installation precautions:

In the installation process, it is based on the standard. Improper installation often hinders the normal operation of the electromagnetic pulse valve. It directly affects the effect of the operation of the dust collector, and summarizes the installation and debugging of the electromagnetic pulse valve of the previous dust removal system. The common faults have the following phenomena:


1. The rated voltage of the installed electromagnetic pulse valve is inconsistent with the supplied working voltage. When energized, the electromagnetic pulse valve will not operate or the coil will burn out.


2. Before installing the electromagnetic pulse valve, be sure to purge the pipeline to ensure that there are no metal powder, rust and other impurities in the pipeline to block the electromagnetic pulse valve. The compressed air of the pipeline medium must be clean.


3. The electromagnetic pulse valve is oriented, and the reverse direction of the electromagnetic pulse valve will cause the valve to be closed and to be ventilated. The installation method should be selected according to the same model and media flow direction on the instruction manual.


4. When threading, tighten the connecting bolts and properly use the adhesive or sealing tape to prevent leakage.


5. The bolts at the connection of the electromagnetic pulse valve are not tightly sealed, and there is leakage. The compressed air cannot reach the working pressure value.


Focus on your demands, Offer you best solution:


√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing


Welcome to your any question and inquiry!

Company Profile

Ningbo Brando Hardware Co., Ltd

* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years.

 

* We have served customers from Europe, North America, Middle east, Southeast Asian by designing and manufacturing for their automation fluid control applications, related to industries of pneumatic automation equipment, food beverage dispenser, agricultural irrigation, printing and dyeing, dust collector, home appliance, automobile, textile, refrigeration, etc.

 

Since the company's inception, we are dedicated to providing high quality products and service to our customers. With focusing on our customers' demands, at before production we discuss technical points according to applications with customers to reduce mistake and save cost for both sides. During production, we use high precision CNC machine, machining center to control dimensions and improve productivity. At beginning and mid of machining, our senior inspectors check quality regularly by recording data on documents as per ISO9001 management system. Before shipment, our staff make testing and complete inspection one piece by one piece to ensure the products without defect when reached our customer's hands.

 

Ningbo Brando Hardware Co., Ltd will offer you best service with fast response, let's make the fluid control application more widely and smartly.

 

 

Product Categories:

1. Solenoid Valve
2. Solenoid Coil
3. Solenoid Armature
4. Solenoid Coil Connector
5. Solenoid Valve Timer
6. Pulse Valve
7. Valve Diaphragm
8. Pulse Controller
9. Refrigeration Valve
10. Pneumatic Valve
11. Pneumatic Fitting
12. Pneumatic Cylinder
13. Pneumatic Filter Regulator Lubricator
14. Pneumatic Vibrator
15. Ball Valve
16. Butterfly Valve
15. and so on

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Ningbo Brando Hardware Co., Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Aluminum SS30 3 / 4 Inch Port Pulse Jet Solenoid Valve Z Type SCG353A043 wholesale

Aluminum SS30 3 / 4 Inch Port Pulse Jet Solenoid Valve Z Type SCG353A043

China Normally Close Threaded Ports Pneumatic Pulse Valve Similar As CA45T RCA45T wholesale

Normally Close Threaded Ports Pneumatic Pulse Valve Similar As CA45T RCA45T

China CA76MM 220V AC 50/60HZ Pneumatic Pulse Valve , Dust Collector Pneumatic Diaphragm Valve wholesale

CA76MM 220V AC 50/60HZ Pneumatic Pulse Valve , Dust Collector Pneumatic Diaphragm Valve

China Right Angle Aluminium Pneumatic Pulse Valve CA50T QR DIN43650A SS304 Ferrule wholesale

Right Angle Aluminium Pneumatic Pulse Valve CA50T QR DIN43650A SS304 Ferrule

China 220V AC 24V DC DN20 3/4 Inch CA20T Normally Closed Right Angle Diaphragm Dust Collector Pulse Valve wholesale

220V AC 24V DC DN20 3/4 Inch CA20T Normally Closed Right Angle Diaphragm Dust Collector Pulse Valve

China SCG353A051 - G2 1/2 Orifice Size 62mm Threaded Series 353 Dust Collector Dual Pulse Valves Integral Dual Stage wholesale

SCG353A051 - G2 1/2 Orifice Size 62mm Threaded Series 353 Dust Collector Dual Pulse Valves Integral Dual Stage

China SCG353A043 - G3/4 Orifice Size 20mm Threaded Dust Collector Pulse Valves Aluminium Body NBR Seal Series 353 wholesale

SCG353A043 - G3/4 Orifice Size 20mm Threaded Dust Collector Pulse Valves Aluminium Body NBR Seal Series 353

China RCA45FS GOYEN Type 1.5'' Flanged Remote Pilot Pulse Valve For Dust Collector wholesale

RCA45FS GOYEN Type 1.5'' Flanged Remote Pilot Pulse Valve For Dust Collector

China 2'' Manifold Flat Mount Full Immersion Pulse Jet Valve For Dust Collector 24V 220V wholesale

2'' Manifold Flat Mount Full Immersion Pulse Jet Valve For Dust Collector 24V 220V

China 3-8V5 Goyen Type Solenoid Pilot Valve Enclosure Box RCA3-8V5 220V 110V 24V wholesale

3-8V5 Goyen Type Solenoid Pilot Valve Enclosure Box RCA3-8V5 220V 110V 24V

China 1'' RCA25T Goyen Type Remote Control Valve For Dust Collector wholesale

1'' RCA25T Goyen Type Remote Control Valve For Dust Collector

Inquiry Cart 0