Home /

200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08

Send your message to this supplier
*From:
Your email address is incorrect!
To:Ningbo Brando Hardware Co., Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08 from wholesalers
  • Buy cheap 200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08 from wholesalers
  • Buy cheap 200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08 from wholesalers
  • Buy cheap 200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08 from wholesalers
  • Buy cheap 200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08 from wholesalers

200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08

Ask Latest Price
Brand Name:OEM
Model Number:4V220-08
Certification:CE、ISO
Price:Negotiation
Payment Terms:T/T, PayPal, Western Union
Supply Ability:100000pcs per month
Delivery Time:Negotiation
Company Data
Verified Supplier
Contact Person Brandon Bao
Business Type: Manufacturer Distributor/Wholesaler Exporter Seller
Officials: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

1/4 inch Inlet and Outlet 200 Series Electromagnetic Pneumatic Valve 4V220-08


4V 200 Series Solenoid Pneumatic Valve,Wiring Form for Lead Wire or Connector type.The inner hole is processed by a special process, the friction resistance is small, the starting air pressure is low, and the service life is long.Can be integrated with the base to save installation space.


Product NameModelTypeMaterialWorking VoltageOperating PressureEffective AreaPower ConsumptionAction FrequencyInsulation Grade
Pneumatic Solenoid Valve4V130C-062 Position 5-WayAluminum Alloy

DC12V DC24V

AC110V AC220V

0.15-0.8MPa12mm²AC:2.5VA DC:2.5W5Cycle per SecondIP65

200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08


200 Series Pneumatic Pulse Valve / Electromagnetic Solenoid Valve 4V220-08


Troubleshooting:
1. The solenoid valve does not work after being energized.

Check if the power wiring is defective → rewire and connector connection
Check if the power supply voltage is within the ± working range - → adjust the normal position range
Whether the coil is desoldered → re-weld
Short circuit of coil → change coil
Is the working pressure difference inappropriate → adjust the differential pressure → or replace the proportional solenoid valve
Fluid temperature is too high → replace the proportional solenoid valve
There are impurities that cause the main valve core and moving iron core of the solenoid valve to be stuck → cleaning. If there is seal damage, replace the seal and install the filter.
The viscosity of the liquid is too high, the frequency is too high and the life is up to → replace the product


2, the solenoid valve can not be closed

The seal of the main spool or the iron core has been damaged → replace the seal
Whether the fluid temperature and viscosity are too high → replace the solenoid valve of the opposite port
There are impurities entering the solenoid valve to produce the valve core or moving iron core → cleaning
Spring life has reached or deformed → replaced
The orifice balance hole is blocked → timely cleaning
The working frequency is too high or the life is up to → re-elect or update the product


3. Other situations

Internal leak → check if the seal is damaged and the spring is not properly assembled
External leakage → loose connection or seal is broken → tighten the screw or replace the seal
There is noise when energized → the solid parts on the head are loose and tightened. The voltage fluctuation is not within the allowable range and the voltage is adjusted. The iron core suction surface is dirty or uneven, and it is cleaned or replaced in time.


Installation note:

1. When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium. Do not install in places where there is direct dripping or splashing. The solenoid valve should be installed vertically upwards;
2. The solenoid valve should ensure normal operation within the fluctuation range of 15%-10% of the rated voltage of the power supply;
3. After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be energized several times to make it suitable for use after being warmed up;
4. The solenoid valve should be thoroughly cleaned before installation. The medium to be passed should be free from impurities. Install the filter in front of the valve;
5. When the solenoid valve is faulty or cleaned, a bypass device should be installed to ensure the system continues to operate.

Company Profile

Ningbo Brando Hardware Co., Ltd

* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years.

 

* We have served customers from Europe, North America, Middle east, Southeast Asian by designing and manufacturing for their automation fluid control applications, related to industries of pneumatic automation equipment, food beverage dispenser, agricultural irrigation, printing and dyeing, dust collector, home appliance, automobile, textile, refrigeration, etc.

 

Since the company's inception, we are dedicated to providing high quality products and service to our customers. With focusing on our customers' demands, at before production we discuss technical points according to applications with customers to reduce mistake and save cost for both sides. During production, we use high precision CNC machine, machining center to control dimensions and improve productivity. At beginning and mid of machining, our senior inspectors check quality regularly by recording data on documents as per ISO9001 management system. Before shipment, our staff make testing and complete inspection one piece by one piece to ensure the products without defect when reached our customer's hands.

 

Ningbo Brando Hardware Co., Ltd will offer you best service with fast response, let's make the fluid control application more widely and smartly.

 

 

Product Categories:

1. Solenoid Valve
2. Solenoid Coil
3. Solenoid Armature
4. Solenoid Coil Connector
5. Solenoid Valve Timer
6. Pulse Valve
7. Valve Diaphragm
8. Pulse Controller
9. Refrigeration Valve
10. Pneumatic Valve
11. Pneumatic Fitting
12. Pneumatic Cylinder
13. Pneumatic Filter Regulator Lubricator
14. Pneumatic Vibrator
15. Ball Valve
16. Butterfly Valve
15. and so on

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Ningbo Brando Hardware Co., Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China 1/2'' Double Coils 5/2 Way Pneumatic Cylinder Valve 4V420-15 0.15-0.8MPa wholesale

1/2'' Double Coils 5/2 Way Pneumatic Cylinder Valve 4V420-15 0.15-0.8MPa

China Silver Color Lead Wire or Connector type 5/3 Way Pneumatic Air Control Valve 4V430-15 wholesale

Silver Color Lead Wire or Connector type 5/3 Way Pneumatic Air Control Valve 4V430-15

China 5/2 Way 1/8'' NPT 4V120-06 Internal Pilot Aluminum Alloy Double Solenoid Pneumatic Valve AC220V DC24V wholesale

5/2 Way 1/8'' NPT 4V120-06 Internal Pilot Aluminum Alloy Double Solenoid Pneumatic Valve AC220V DC24V

China Cng Injector Rails Solenoid Valve Parts Valve Stems 22g Two Way Type wholesale

Cng Injector Rails Solenoid Valve Parts Valve Stems 22g Two Way Type

China Two Position Five Way Cylinder Operated Valve G1/8 Inner Guide Type wholesale

Two Position Five Way Cylinder Operated Valve G1/8 Inner Guide Type

China 5/2 Way 4V420-15 1/2" NPT Double Coil Electrical Air Directional Valve Aluminum Body Automation Component wholesale

5/2 Way 4V420-15 1/2" NPT Double Coil Electrical Air Directional Valve Aluminum Body Automation Component

China BSP 1/4" 4V310-08 AirTAC Type Pneumatic Solenoid Valve 5/2 Way Single Solenoid DC12V DC24V wholesale

BSP 1/4" 4V310-08 AirTAC Type Pneumatic Solenoid Valve 5/2 Way Single Solenoid DC12V DC24V

China 1/4" 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve 2/2 Way Direct Acting NC wholesale

1/4" 2V025-08 Airtac Type Fluid Control Pneumatic Solenoid Valve 2/2 Way Direct Acting NC

China 1/8" NPT 4V110-06 AIRTAC Type Pneumatic Solenoid Air Valve 2 Position 5 Way DC24V AC220V wholesale

1/8" NPT 4V110-06 AIRTAC Type Pneumatic Solenoid Air Valve 2 Position 5 Way DC24V AC220V

China SS304 Pneumatic Clutch Actuator Solenoid Valve Replacement For WABCO Clutch Servo 9701500080 Of MERCEDES ACTROS MP2 wholesale

SS304 Pneumatic Clutch Actuator Solenoid Valve Replacement For WABCO Clutch Servo 9701500080 Of MERCEDES ACTROS MP2

China Airtac Type Pneumatic Air Pilot Valve Double Single 5/2 Way 5/3 Way wholesale

Airtac Type Pneumatic Air Pilot Valve Double Single 5/2 Way 5/3 Way

Inquiry Cart 0