Environmental Temperature and Humidity Test Chamber For PV Solar Panel Test
The environmental room can heat all types of batteries.
These special tests for sensitive products, human safety and
product safety can be broadly considered and solutions based on the
risks involved.
In the case of possible leakage of the device under test:
exhaust pipe
Manufacture of photovoltaic (PV) module testing standard
environmental room.
In accordance with the standards achieved, important special
considerations were taken into account in.
The study and realization of these conference rooms:
Develop an intelligent system chart that can be adapted to most PV
panels to simplify processing when loading and storing
Humidity production and ventilation are particularly suitable for
standard requirements
Install and direct electrical appliances through our software
Spirale 3 to allow the "down voltage" panel to perform continuity
testing or power testing during the test.
,
Main Parameters
Model | KMHW | |||||||
Safety Devices | No fuse breaker, over pressure, over heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection | |||||||
Standard accessories | Sight window*1, cable port ( portΦ50mm ) *1, chamber lamp*1, status indicator | |||||||
Control System | Balanced Temperature & Humidity Control System | |||||||
Refrigeration system | Water Cooled | |||||||
Semi-hermetic compressor, single stage or cascade refrigeration system, | ||||||||
CFC free refrigerant ( HFC-507 and HFC-23 ) | ||||||||
Controller | Panel | 7-inch LCD Touch panel, Chinese or English display selectable | ||||||
Operation model | Program or fix point running | |||||||
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | |||||||
Accuracy | Temp.:0.1% of F.S ± 1 digit Humidity:0.1% of F.S ± 1 digit | |||||||
Input | Temp.: pt-100, Humidity: pt-100 or ~5V DCV | |||||||
Comm.port | RS-232 or RS-485 ( Softawre is option) | |||||||
Temp | Maximum: 80 ºC,120 ºC; Minimum: -60 ºC, -50 ºC, -40 ºC, -30 ºC, -20 ºC, -10 ºC, 0 ºC | |||||||
Humidity | 10%, 20%, 30% ~ 95% | |||||||
Heat up time | +30 ºC~+90 ºC, Within 60 min | |||||||
Pull down time | +30 ºC ~ -55 ºC, -40 ºC,Within 80 min | |||||||
Interior material | Stainless Steel Plate | |||||||
Exterior material | Baked Painting Steel Or Stainless steel | |||||||
Insulation material | Rigid polyurethane foam | |||||||
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
Characteristics
Performance of the excellent
Precision microcomputer control temperature and humidity system,
with PID control refrigerant flow, the system of heating /
humidification reduced, to achieve low power consumption, energy
saving, carbon reduction effect, cooling, heating, humidity control
intelligent electronic control, long-term stable use.
The following are the same as the "
Structural flexibility
The panels used in our room are 4 "(100mm or 150mm) thick
polyurethane foam sandwiched between stainless steel interior and
steel strip appearance. Assembled boxes are self-supporting. So do
not need heavy structural parts. Different door sizes , Floor
upgrades, access ports and other modifications are possible.
The most customizable test range.